Optimasi Fasad Bangunan untuk Efisiensi Energi Berdasarkan Analisis OTTV pada Ruang Dosen Politeknik Negeri Sriwijaya

Nurlatifah Fajriaty Ronyta, Ricky Ravsyan Alhafez, Karina Karina, Ria Dwi Putri, Doni Sastra

Abstract


Building facade optimization plays an essential role in improving the energy efficiency of buildings, particularly in tropical regions such as Indonesia, which experience high solar radiation intensity. Educational institution buildings, such as the Lecturer Room of the D-IV Building Architecture Program at Politeknik Negeri Sriwijaya, Keramasan Campus, represent one of the building types with high energy demand for thermal comfort and lighting. The urgency of this research lies in the need for façade design strategies that can reduce cooling loads without compromising thermal and visual comfort, while also complying with energy efficiency standards through the calculation of the Overall Thermal Transfer Value (OTTV). This study aims to examine and optimize the building facade design based on OTTV values in accordance with SNI 03-6389-2011 and the Ministry of Energy and Mineral Resources Regulation (Permen ESDM) No. 02/2021. The research employs a quantitative approach consisting of field surveys, physical data collection of the building, thermal modeling, and simulation of façade optimization through the combination of shading devices and low-e glass. The results show that the existing façade design has an OTTV value of 43.21 W/m², exceeding the maximum limit of 35 W/m². After optimization through the application of horizontal shading devices and the use of low-e glass, the OTTV value decreased to 32.87 W/m², meeting the energy efficiency standard. This research provides recommendations for energy-efficient facade design and serves as a reference for designing educational buildings in hot-humid tropical climates. The findings are expected to contribute to the development of sustainable architectural design practices within campus environments.

Keywords


building facade, energy efficiency, OTTV, shading, tropical architecture

Full Text:

PDF

References


Al-Obaidi, K. M., Ismail, M., & Abdul Rahman, A. M. (2014). Passive cooling techniques through reflective and radiative roofs in tropical houses in Southeast Asia: A literature review. Frontiers of Architectural Research, 3(3), 283–297. https://doi.org/10.1016/j.foar.2014.06.002

Al-Tamimi, N. A., & Fadzil, S. F. S. (2011). The Potential of Shading Devices for Temperature Reduction in High-Rise Residential Buildings in the Tropics. Procedia Engineering, 21, 273–282. https://doi.org/10.1016/j.proeng.2011.11.2015

Attia, S., Gratia, E., De Herde, A., & Hensen, J. L. M. (2012). Simulation-based decision support tool for early stages of zero-energy building design. Energy and Buildings, 49, 2–15. https://doi.org/10.1016/j.enbuild.2012.01.028

Badan Standardisasi Nasional. (2011). Konservasi energi selubung bangunan pada bangunan gedung (SNI 03-6389-2011). Jakarta.

Badan Standardisasi Nasional. (2020). Konservasi energi sistem tata udara pada bangunan gedung (SNI 6389:2020). Jakarta.

Givoni, B. (1998). Climate Considerations in Building and Urban Design. Canada: Wiley.

Hien, W. N., Liping, W., Chandra, A. N., Pandey, A. R., & Xiaolin, W. (2005). Effects of double glazed facade on energy consumption, thermal comfort and condensation for a typical office building in Singapore. Energy and Buildings, 37(6), 563–572.

Okeil, A. (2010). A holistic approach to energy efficient building forms. Energy and Buildings, 42(9), 1437–1444. https://doi.org/10.1016/j.enbuild.2010.03.013

Poirazis, H., Blomsterberg, Å., & Wall, M. (2008). Energy simulations for glazed office buildings in Sweden. Energy and Buildings, 40(7), 1161–1170. https://doi.org/10.1016/j.enbuild.2007.10.011

Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008). A review on buildings energy consumption information. Energy and Buildings, 40(3), 394–398. https://doi.org/10.1016/j.enbuild.2007.03.007

Szokolay, V. S. (2014). Introduction to Architectural Science: The Basis of Sustainable Design (3rd ed.) (3rd Edition). London: Routledge. https://doi.org/10.4324/9781315852409

Suryan, V., Amalia, D., Martadinata, M. I., Septiani, V., Nurfitri, M. A., Silitonga, E., & Chandra, P. W. A. (2024). Eco airport design: Rancangan gedung terminal ramah lingkungan pada bandar udara. Jurnal Talenta Sipil, 7(2), 759-773. https://doi.org/10.33087/talentasipil.v7i2.583

Suripto, S., Abdi, M. H., & Manurung, E. H. (2022). Evaluasi penerapan green construction proyek pembangunan gedung rektorat Kampus UIII. Jurnal Talenta Sipil, 5(1), 134-143. https://doi.org/10.33087/talentasipil.v5i1.106

Tzempelikos, A., & Athienitis, A. K. (2007). The impact of shading design and control on building cooling and lighting demand. Solar Energy, 81(3), 369–382. https://doi.org/10.1016/j.solener.2006.06.015

Zain-Ahmed, A., Sopian, K., Othman, M. Y. H., Sayigh, A. A. M., & Surendran, P. N. (2002). Daylighting as a passive solar design strategy in tropical buildings: a case study of Malaysia. Energy Conversion and Management, 43(13), 1725–1736. https://doi.org/10.1016/S0196-8904(01)00007-3




DOI: http://dx.doi.org/10.33087/talentasipil.v9i2.1332

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Jurnal Talenta Sipil, Faculty of Engineering, Batanghari University
Adress: Fakultas Teknik, Jl.Slamet Ryadi, Broni-Jambi, Kec.Telanaipura, Kodepos: 36122, email: talentasipil.unbari@gmail.com


Creative Commons License This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.