Perbandingan Daya Dukung Pondasi Tiang Pancang Berdasarkan Data SPT Dan Hasil Uji Pile Driving Analyzer pada Gedung Kantor Walikota Baru Mataram

Serdian Eska Cahya, Hafis Hamdani, Ahmad Zarkasi

Abstract


The construction of the Mataram Mayor's Office requires pile foundations with adequate bearing capacity to support the building load and improve the quality of public services. This study analyzes the bearing capacity of pile foundations based on SPT test data using several calculation methods, and compares them with the results of the PDA dynamic test. By comparing several bearing capacity calculation methods, this study aims to identify the level of accuracy and deviation of theoretical estimation results from actual conditions in the field. The research method used is quantitative analysis by utilizing Standard Penetration Test (SPT) test data as the basis for calculating the bearing capacity of pile foundations using several empirical methods, namely the O'Neil & Reese, Luciano Decourt, and Briaud et al. The results show that the bearing capacity values of pile foundations calculated based on SPT test data using various empirical methods differ from the results of the PDA dynamic test, but are still within a technically acceptable range. These differences are influenced by soil characteristics and the assumptions of each method, so that certain methods tend to show results that are closer to actual conditions in the field. Pile foundation planning relies not only on theoretical calculations based on SPT data but also combines them with PDA dynamic test results to improve the accuracy and reliability of the foundation design. Furthermore, the choice of bearing capacity calculation method must be adapted to local soil conditions to ensure more representative and safe planning results.

Keywords


piles, bearing capacity, SPT, PDA, foundation.

Full Text:

PDF

References


Ahmad, L. G., & Surahman, M. (1957). Discussion of “Penetration Tests and Bearing Capacity of Cohesionless Soils.” Journal of the Soil Mechanics and Foundations Division, 83(1), 65–74. https://doi.org/10.1061/jsfeaq.0000034

Djarwanti, N., I, R. H. D. H., & Arganata, O. F. (2022). Korelasi Daya Dukung Pondasi Tiang Bor dengan Metode Reese and O’Neill terhadap Metode Terzaghi and Peck Berdasarkan Hasil Uji SPT. e-Jurnal Matriks Teknik Sipil, September, 775–781.

Dwina, D. O., Hariyadi, & Hamdani, H. (2024). Analisis Kapasitas Fondasi Tiang Pancang Di Dermaga Labuhan Lombok. Spektrum Sipil 11(2), 139–148.

Fadilla, R. N., Pradiptiya, A., Sipil, J. T., & Jakarta, P. N. (2022). Lisensi Lisensi Creative Commons Atribusi 4.0 Internasional Analisis Daya Dukung Pondasi Spun Pile Dievaluasi Dengan Kalendering Dan PDA. 3(2), 18–25. https://doi.org/10.52158/jaceit.v3i2.394

Faruha, A., & Ridwan, M. (n.d.). Analisa Perhitungan Daya Dukung Pondasi Tiang Pancang Dibandingkan Dengan Daya Dukung Hydraulik Jacking System Dan Pile Driving Analyzer (Pda) Test Pada Proyek Pembangunan Gedung Perpustakaan Sekolah Tinggi Agama Islam Negeri Kediri. 1–10. Jurnal Rekayasa Teknik Sipil, Universitas Negeri Surabaya

Ginting, S. V. N. B., Irwan, & Nurmaidah. (2019). Analysis Calculation of Carryng Capacity Pile Foundation Overpass Sei. 3(1), 40–48. https://doi.org/10.31289/jcebt.v3i1.2460

Livia, L., & Suhendra, A. (2018). Studi Kapasitas Tiang Bor Berdasarkan Metode Pile Driving Analyzer (Pda) Dan Load Cell. JMTS: Jurnal Mitra Teknik Sipil, 1(1), 82. https://doi.org/10.24912/jmts.v1i1.2245

Mardianti, I. Y., Nuklirullah, M., & Dwina, D. O. (2022). Analisis Daya Dukung Pondasi Tiang Pancang Berdasarkan Data Sondir (Studi Kasus : Pembangunan Gedung Rumah Sakit Pendidikan Universitas Jambi). Menara Jurnal Teknik Sipil 17(2), 51–60.

Melisa, & Junaidi. (2020). Kapasitas Dukung Aksial Pondasi Bored Pile Menurut O ’ Neil & Reese Dan Coyle & Castello ( Studi Kasus : Fly Ove R Simpang Ska ). Jurnal Inovtek Seri Teknik Sipil Dan Aplikasi (Tekla) 2(1), 33–40.

Novita Br Ginting, S. V., Irwan, I., & Nurmaidah, N. (2019). Analisa Perhitungan Daya Dukung Pondasi Tiang Pancang Overpass Sei Semayang Sta. 0+350 Pada Proyek Pembangunan Jalan Tol Medan-Binjai. Journal of Civil Engineering, Building and Transportation, 3(1), 40. https://doi.org/10.31289/jcebt.v3i1.2460

Nurhidayanti, Mahfud, & Huda, M. (1996). Analisa daya dukung pondasi tiang pancang. Jurnal Teknik Sipil (Politeknik Negeri Balikpapan)

Rizki Prananda, M., Abrar, A., Jenita Marbun, N., Prananda, Mr., Studi Teknik Sipil, P., Tinggi Teknologi Dumai Jl Utama Karya Bukit Batrem, S. I., Studi Teknik Industri, P., & Tinggi Teknologi Dumai Jl Utama Karya, S. (2024). Analisis Daya Dukung dan Efesiensi Pondasi Tanki CPO Kapasitas 1000 Kiloliter Studi Kasus PT.Energi Unggul Persada. Juli, Jurnal Slump Tes3(1), 52–60.

Sarifah, J., Tanjung, D., & Marpaung, T. R. (2025). Analisis Daya Dukung Pondasi Bored Pile Berdasarkan Data SPT Pada Proyek Pembangunan RSUD Kota Yogyakarta. Jurnal Teknik Sipil (JTSIP) 4(1), 1–143.

Zulfiqar, M., & Hudori, M. (2023). Studi Komparatif Daya Dukung Pondasi Tiang Pancang Berdasarkan Hasil Pile Driving Analyzer Test dan N-SPT. Jurnal Talenta Sipil, 6(2), 229. https://doi.org/10.33087/talentasipil.v6i2.259




DOI: http://dx.doi.org/10.33087/talentasipil.v9i1.1258

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Jurnal Talenta Sipil, Faculty of Engineering, Batanghari University
Adress: Fakultas Teknik, Jl.Slamet Ryadi, Broni-Jambi, Kec.Telanaipura, Kodepos: 36122, email: talentasipil.unbari@gmail.com


Creative Commons License This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.